<p>I plan to map the other controller card connections to RJ45 too.
Will try to keep power on pin 1 and ground on pin 2, and put control
signals on the rest. One sad issue is that the print head controllers
-(DC motor, PWM and temerature) in total uses 9 pins - one to many for
+(DC motor, PWM and themerature) in total uses 9 pins - one to many for
the RJ45. :( Guess I will have to find another connector for these. I
will have to keep an eye on the plans to make print heads
hot-swapable, and see what kind of connector will be used there.
+I decided to use one connector for the DC motor controller, and one
+for the PWM and temperature controller. Here is the DC motor
+controller pinout. Decided to keep the directions in one pair and the
+PWM signals in another pair.
+<table>
+<tr><th align="left">RJ45</th> <th align="left">Stepper motor controller</th></tr>
+<tr><td>pin 1 org/wht (unused)</td> <td>VCC</td></tr>
+<tr><td>pin 2 org</td> <td>GND</td></tr>
+<tr><td>pin 3 grn/wht</td> <td>DIR A</td></tr>
+<tr><td>pin 4 blu</td> <td>PWM A</td></tr>
+<tr><td>pin 5 blu/wht</td> <td>PWM B</td></tr>
+<tr><td>pin 6 grn</td> <td>DIR B</td></tr>
+<tr><td>pin 7 brn/wht (unused)</td> <td>N/A</td></tr>
+<tr><td>pin 8 brn (unused)</td> <td>N/A</td></tr>
+</table>
+
+Here is the PWM and temperature sensor controler pinout. Decided to
+group these two together, as both are connected to the heating chamber
+and to save RJ45 connectors.
+
+<table>
+<tr><th align="left">RJ45</th> <th align="left">controllers</th></tr>
+<tr><td>pin 1 org/wht (unused)</td> <td>Temp driver VCC</td></tr>
+<tr><td>pin 2 org</td> <td>Temp driver GND</td></tr>
+<tr><td>pin 3 grn/wht</td> <td>Temp driver input</td></tr>
+<tr><td>pin 4 blu</td> <td>PWM driver GND</td></tr>
+<tr><td>pin 5 blu/wht</td> <td>PWM driver PWM1</td></tr>
+<tr><td>pin 6 grn</td> <td>N/A</td></tr>
+<tr><td>pin 7 brn/wht (unused)</td> <td>PWM driver PWM2</td></tr>
+<tr><td>pin 8 brn (unused)</td> <td>PWM driver PWM3</td></tr>
+</table>
- z axes - remove springs and spacers
Elfa - 80-899-97 eller 80-900-29, hhv 12 og 19 mm bred, og dyr :)
<divid> pere: 80-907-07 for 33 mm
+
+ELFA 43-566-08 "Kontakthus 2,54mm, 3-pol"